22 - LOW-VOLTAGE AND CAN BUS TESTING

Our laboratory conducts comprehensive low-voltage testing on 12 V, 24 V, and 48 V systems with currents up to 200 A. Testing includes transient voltage evaluation, load dump scenarios, and various power failure simulations. Control line testing covers pulse response, reset behavior, interruptions, and polarity reversal using specialized equipment including 4-quadrant voltage drop simulators, automotive transient generators, and electronic/mechanical switching systems.
Our facility features two dedicated testing cells each capable of testing up to six samples in parallel, significantly reducing validation time. Comprehensive monitoring utilizes 48-channel DAQ systems with 1 MS/s sampling, supported by active liquid cooling and integration with climatic chambers. All testing complies with ISO 16750, ISO 7637-2, and customer-specific standards, with complete project management and detailed analysis support throughout the validation process.
- Voltage range 12 V, 24 V and 48 V; up to 200 A
- Transient over-voltage / under-voltage
- Load dump
- Other power fail tests
- Pulses tests
- Reset behaviour
- Interruptions
- Polarity reversal
- Other fail tests
- Power supply range 12 V, 24 V and 48 V; up to 200 A
- 4-quadrant voltage drop simulator (VDS 200Q25)
- Automotive power fail simulator (PFM 200N)
- Ultra compact simulators for Automotive transients (UCS 200N50)
- Capacitive coupling clamp for Automotive testing
- Electronic switch BS 200N100
- Artificial network AN 200N100; AN 2050
- Mechanical switch BSM 200N40 (12/24 V DC/40 A)
- Load dump generator (LD 200N100)
- 2 testing cells
- Up to 6 samples tested in parallel / cell
- Monitoring DAQ system up to 48 channels; sampling rate up to 1 MS/s
- Active cooling of DUT by liquid
- Advanced online safety conditions (sample protection)
- Climatic loading in chambers
- Deep analyses and customer support
- Validation project management
- ISO 16750
- ISO 7637-2
- Customer standards